Receptacles Led
![]() |
![]() Lot 10 Ivory 20A Ground Fault Receptacles w LED GFCI UL $40.00 Time Remaining: 9d 3h 6m Buy It Now for only: $40.00 |
![]() GFCI Receptacle 15A 125V White LED 2008 UL Tamper Resistant $9.00 Time Remaining: 3d 12h 42m Buy It Now for only: $10.00 |
![]() Lot50 Ivory 20A Ground Fault Receptacles w LED GFCI UL $195.00 Time Remaining: 26d 22h 1m Buy It Now for only: $195.00 |
![]() Leviton LED ALARM ISO GND BLUE Surge Receptacle Outlet $21.95 Time Remaining: 20d 23h 4m Buy It Now for only: $21.95 |
![]() Lot 50 Ivory 15A Ground Fault Receptacles w LED GFCI UL Listed $195.00 Time Remaining: 25d 2h 43m Buy It Now for only: $195.00 |
![]() Lot 10 Ivory 15A Ground Fault Receptacles w LED GFCI UL $40.00 Time Remaining: 4d 20h 13m Buy It Now for only: $40.00 |
![]() Leviton RED HOSPITAL LED Receptacle Duplex Outlet 20A $9.95 Time Remaining: 20d 23h 16m Buy It Now for only: $9.95 |
![]() Lot 10 Brown 20A Ground Fault Receptacles w LED GFCI UL $42.00 Time Remaining: 7d 1h 33m Buy It Now for only: $42.00 |
![]() YGF20LL ClassA GFCI 20A 125v Spec Grade LED Receptacle Outlet TEST RESET Buttons $9.95 Time Remaining: 29d 23h 34m Buy It Now for only: $9.95 |
![]() 2 20 AMP LIGHT ALMOND GFCI RECEPTACLES WITH LED $15.99 Time Remaining: 15d 16h 55m Buy It Now for only: $15.99 |
![]() Leviton Ivory HOSPITAL Receptacle LED Duplex Outlet 20A $9.95 Time Remaining: 28d 1h 39m Buy It Now for only: $9.95 |
![]() Leviton White Decora LED HOSPITAL Receptacle Outlet 15A $9.99 Time Remaining: 9d 6h 57m Buy It Now for only: $9.99 |
![]() Leviton White HOSPITAL Receptacle LED Duplex Outlet 20A $9.95 Time Remaining: 23d 2h 48m Buy It Now for only: $9.95 |
![]() 10 Leviton LED ALARM ISO GND BLUE Surge Receptacles $194.95 Time Remaining: 20d 23h 1m Buy It Now for only: $194.95 |
![]() Leviton RED Decora LED HOSPITAL Receptacle Outlet 15A $9.99 Time Remaining: 5d 10h 32m Buy It Now for only: $9.99 |
![]() Leviton Brown Decora LED Surge Receptacle Duplex Outlet 15A 5280 A $16.95 Time Remaining: 15d 19h 55m Buy It Now for only: $16.95 |
![]() 2 HUBBELL White LED GFCI Receptacle 20A 125V New $17.00 Time Remaining: 5d 20h 34m Buy It Now for only: $19.00 |
![]() 10 Leviton Ivory Decora LED HOSPITAL Receptacle Outlets $109.95 Time Remaining: 5d 4h 19m Buy It Now for only: $109.95 |
![]() Leviton White Decora LED HOSPITAL Receptacle Outlet 20A $12.95 Time Remaining: 24d 5h 57m Buy It Now for only: $12.95 |
![]() Leviton Ivory Decora LED HOSPITAL Receptacle Outlet 20A $11.99 Time Remaining: 5d 4h 24m Buy It Now for only: $11.99 |
![]() Lot 50 Brown 20A Ground Fault Receptacles w LED GFCI UL $205.00 Time Remaining: 7d 1h 36m Buy It Now for only: $205.00 |
![]() Leviton RED Decora LED HOSPITAL Receptacle Outlet 20A $12.95 Time Remaining: 9d 7h 5m Buy It Now for only: $12.95 |
![]() Leviton Brown LED Surge Receptacle Outlet ALARM 20A $21.95 Time Remaining: 20d 23h 4m Buy It Now for only: $21.95 |
![]() 3 GFCI Receptacle 15A 125V White LED 2008 UL Tamper Resistant $31.00 Time Remaining: 25d 10h 53m Buy It Now for only: $31.00 |
![]() Leviton RED HOSPITAL LED Surge Receptacle Outlet ALARM $23.95 Time Remaining: 1d 3h 40m Buy It Now for only: $23.95 |
![]() 10 Leviton Red Decora LED HOSPITAL Receptacles Outlets $89.95 Time Remaining: 2h 12m Buy It Now for only: $89.95 |
![]() 10 Leviton White Decora LED HOSPITAL Receptacle Outlets $109.95 Time Remaining: 23d 2h 56m Buy It Now for only: $109.95 |
![]() Leviton BLUE ISOLATED GND Hospital LED Surge Receptacle $26.95 Time Remaining: 17d 5h 32m Buy It Now for only: $26.95 |
![]() 25 LOT GFCI GFI Receptacle + DOUBLE SWITCH LED LIGHT HIGH END ITEM $229.00 Time Remaining: 18d 3h 42m Buy It Now for only: $229.00 |
![]() Lot 15 SmartLock White Hospital Grade GFCI GFI Receptacles 20A LED 8898 HGW Whit $149.99 Time Remaining: 11d 4h 9m Buy It Now for only: $149.99 |
Receptacles Led

How to repair Dell MK911 ac adapter
Your laptop goes dead and you don't understand why because it's plugged in. The very first thing you should look for is status LEDs. The transformer brick or ac power adapter usually has a status led on it to show that it's plugged into a good outlet and is functioning. If the laptop power adapter LED is not lit and the cord is firmly seated in both the transformer and the wall outlet, then the AC adapter is probably bad. But troubleshooting most power problems takes a little more effort. Fortunately, it's also common for the failure to be the power cord itself, as I've noted with some Toshiba models. Many HP and Compaq models use "L" connectors which are less prone to failure, and Sony and Dell cords seem more robust as well, but it's always a possibility. It seems to me I've seen "L" connectors on Dell MK911 ac adapter as well.
If the status LEDs on the laptop blink when you wiggle the power cord or if they can be kept on if you position the cord just right, the failure is either the power cord or the power connector inside the laptop. Of the two, you want the problem to be the power cord because it's much easier to fix. A power cord can look perfectly good (see above) but be broken inside, normally as result of letting it dangle off the back of the laptop when you work on your lap. The length of cable running from the Dell MK911 ac adapter to the laptop is shielded coaxial cable, with the inner conductor attached to the inner part of the barrel connector and the outer part serving as ground. The actual AC power cord is often detachable from the power adapter and is unlikely to fail as long as it's seated.
Many power cords also include a large choke, probably a ferrite, which I assume is to prevent RF interference generated by the laptop from leaking back onto the cord and turning the length between the laptop and the power adapter into an antenna. Frankly, I just cut them off on a repair if they are close too the barrel connector. It's nice to have a reasonable wire stripper so you can strip the coax in one shot rather than worrying away the sheathing with a cheap tool. You want to take about an inch of the outer sheath off and then twist the braid shield together. Some techs like to preload the braid with solder before tacking it to the power connector, but if there's a tab you can wrap it around first it's not really necessary.
I prefer to buy new connectors than to try to reuse the original for several reasons. First, the original ac power adapter for laptop will have a molded casing on the connector, and the only way to get it off is to hack away a little at a time with a razor. I've done it and effected a repair when I was traveling and had no other choice, but the braided conductor on my Dell notebook was soldered directly to the outside of the barrel rather than having its own solder point, like a replacement connector. It's also very difficult to solder factory connectors without melting the insulator unless you have a hot, fine tip iron. I get my replacement connectors at Radio Shack for a buck or so, bring the original for sizing. The inside and outside diameter have to be an exact match, so you might even want to bring your notebook to the store with you.
If you are working with the cord length still attached to the power adapter, make sure you slide the shell for the new connector onto the cord and faced the right way before you solder on the connector. Otherwise, you'll be faced with doing it all over or just taping the heck out of the connector. The length of the barrel connector that fits into the laptop body is somewhat flexible, too long can work, to short and you may be able to back-off a little on the connector shell. To the left, you can see the inner (yellow) of the laptop power cord soldered to the center tab of the barrel conector, and the braid soldered to the outer tab. If you have a heatshrink gun and tubing you can make a much neater job of it than I'm doing here:-)
Obviously, you don't want the two tabs to touch or it just shorts out, so you can work a little tape around one of the tabs if you are paranoid, but leave room to get the shell on. The shell is actually threaded, as is the connector, so they usually hold together pretty good. Since this particular failure gave me so much grief the first time it happened, I always travel with a spare replacement end for my laptop power cord. While my first replacement is still holding up, should it fail, I can just undo the splice and tape the replacement end on in a matter of minutes. It's unfortunate that so many people buy a new laptop power adapter or even crack their laptop open and start fooling with the inside receptacle when the problem is just the connector on the power cord.
About the Author
What gauge of wire should I use to a light fixture on a 20 amp circuit?
Adding a new circuit to a kitchen counter. Using a 20 amp circuit and a 20 amp T GFI receptacle, so I will be running 12/2 wire from the panel to the GFI.
From there, I plan to add an under-counter fluorescent or LED fixture off of the GFI. Can I use 14/2 for that part of the run, or must it be 12/2 all the way?
@ Lic. Electrician I think Fahr Quad said it best. So I get it - can't lower any section of the run, regardless of it's end use. The light fixture in question is simply a low voltage under-counter model - the kind which comes either as plug-in or wired - no wall switches, nothing extra - just the self-contained unit with it's own off/on switch. Rather than plug it into the receptacle, I plan to wire it onto the GFI (using 12/2 as discussed). I hear conflicting reports from others saying that this application is acceptable. thoughts?
Excellent answer from Deric. The wire size info is correct.
One missing detail to add though....
You are not allowed to use circuits serving the kitchen counter to supply power for lighting. What you are proposing to do is a violation of National Electrical Code.
You need to power the lights from another circuit.
UPDATE:
Your original question did not give details on the lighting. Your update does help. Since you asked for 'thoughts' about powering the lights from the kitchen receptacles, I'm always willing to support my answers.
NEC Section 210.52(B)(1) says that you must have at least two 20 ampere circuits to serve the kitchen and similar areas. (paraphrased. not a direct quote)
Section 210.52(B)(2) says "The two or more small-appliance branch circuits specified in 210.52(B)(1) shall have no other outlets." (Quoted as written in NEC)
For clarification, a lighting outlet is still an outlet (as is a receptacle outlet). This would make direct wiring your lights a code violation. However, if you were to choose to just plug them in to a receptacle, it would be no different than any other appliance/device that you use. No code violation in that case.
Now that you have the facts, as written in the NEC, the choice is up to you.
Top 5 Power Inverters






























